Energy compliance and assessment
SAP, SBEM and operational-energy assessment
Scope of the service
Energy assessments use recorded inputs and assumptions linked to the developing design, with missing evidence and review needs identified.
Typical scope
- SAP, SBEM and Part L assessment scope planning
- Part O overheating assessment where required
- Operational-energy, carbon and energy-use reporting
- Design updates, evidence tracking and improvement options
Compliance and design interfaces
- Building Regulations Approved Documents L and O
- SAP and SBEM methodologies
- CIBSE operational-energy and overheating guidance where required
The scope and outputs are agreed for each appointment.
Assessment, certification and lodgement responsibilities are agreed for the project.
Deliverables
What you receive
A clear record of the design, findings or advice. The documents and level of detail are agreed for your project.
Annual energy use Demonstration data
- Heating
- 42,000kWh42%
- Cooling
- 18,000kWh18%
- Fans & pumps
- 14,000kWh14%
- Lighting
- 16,000kWh16%
- Hot water
- 10,000kWh10%
About this example
How to read the example
- Energy boundary
- Annual delivered energy by end use, shown in kWh/year.
- Demonstration figures
- Synthetic values illustrate report presentation; they are not a benchmark or project prediction.
- Assessment inputs
- Geometry, fabric, occupancy, operating hours, systems and control assumptions.
- Carbon assessment
- Report separately using the energy-carrier split, stated emission factors and assessment year.
- Option comparison
- Compare alternatives using the same assessment boundary and operating assumptions.
- Assessment inputs, model and assumptions register
- Design-stage assessment report and evidence schedule
- Design-stage update reports
- Improvement options and close-out information
When to involve us
When it helps
- Part L route confirmation is required
- SAP or SBEM is needed
- Part O triggers apply
- Operational-energy options must be tested
Useful information
- Architectural geometry and fabric specification
- MEP systems, efficiencies and controls data
- Air permeability and renewable-energy inputs
- Assessment basis and project-control route
Scope and information are agreed for the project stage. See RIBA stages and BG6 responsibilities.
Focused services
Common questions
Can you help with SAP and SBEM assessments?
Assessment scope, required inputs and any assessor or lodgement arrangements are confirmed for the project.
Is overheating also reviewed?
Yes. Part O requirements are included where route and use indicate a need.
Related services
Next step
Discuss your project
Tell us about the building, location and support you need. We can help define the scope and next step.